Transition Point 玻璃轉移點試驗

Transition Point

玻璃轉移點試驗

Transition Point - Dilatometer (ASTM E-228)

廠牌:ORTON/U.S.A.
供應商:建成科學儀器股份有限公司
聯絡電話:02-29103818
定價:與我們聯絡

快速詢價

5246

行動條碼QR Code
玻璃轉移點試驗-行動條碼QR Code

 


The Orton DIL 2010 STD is a standard bench top, horizontal, digital dilatometer that measures the expansion and softening characteristics of a glass specimen from room temperature up to 1,000°C. The Orton software quickly and easily finds the glass transition point (Tg) and the approximated softening point (Ts). By specifying the temperatures, or range of temperatures, the software quickly and easily calculates the Coefficient of Thermal Expansion (CTE) or alpha (a).

The Model DIL 2010 STD comes complete with a Kanthal wound tube furnace, Type S sample/control thermocouple, adjustable contact pressure and a precision LVDT. The fused quartz sample holder and push rod accommodate samples up to 50 mm long (2") and 20 mm (3/4") cross section. The thermal cycle of the furnace is controlled by the user friendly Orton PID Control System and data is stored on the onboard computer.

After the test is run, the data can be downloaded via a RS 232 serial connection to a user supplied computer system. Or if desired, the user supplied computer system can be connected to the Orton controller via the RS 232 serial port for real time test monitoring.

Intuitive, easy-to-use Windows® 95/98/00 based analysis software is provided. The PC can receive up to 32,000 data points (time/temperature/percent linear change) for extremely long runs. Data from up to six runs can be compared. Data can be printed graphically or in tabular form or exported as an ASCII file.

Software features include comparisons against temperature or time; zoom into part of the curve; and examine percent linear change, differential or average coefficient of expansion, calculation of transition and softening point temperatures, a-b quartz transition temperature and coefficient of expansion calculation for any temperature range.

The system is calibrated at Orton with a standard alumina reference sample and calibration file provided. 120 VAC, 15 amp, 50/60 hertz power is required. Options include: atmosphere or vacuum testing, water-cooled head measuring head panel, over-temperature protection, exchangeable furnace and 240 VAC option.

Typical Specifications:

Temperature Range RT to 1,000°C
Sample Size - Max. Length 50 mm
Sample Size - Max. Diameter 20 mm
Probe Rod Contact Pressure > 4 g (adjustable)
Sample Holder/Probe Rod Fused Quartz
Sample/Control Thermocouple Type "S"
LVDT Linear Range ± 2.54 mm
LVDT Linearity 0.10% of output over 50% of nominal range
LVDT Linearity 0.25% of output over the full nominal range
Furnace and Heating Element Tube - Kanthal wire
Power requirement 120 VAC, 15 amp, 50/60 Hz


Controller Specifications:

Programable Segments 20
Heating Rates up to 30°C/minute
Softening Point/Melting Protection User definable

* Descriptions and specifications are subject to change without notice (rev.11.26.02)

  下載本目錄文件請使用 PDF 檔案程式
Download a brochure on the Orton Glass Dilatometer in PDF format (760 kb)

您也可能對以下商品有興趣...

產品關鍵字:

大台北尖端儀器有限公司

最新廠商動態!

WHATMAN代理美國過濾耗材知名大廠;Cytiva代理WHATMAN耗材在2020年;代理濾膜;濾紙;空氣採樣濾紙;
BROOKS質量流量控制器;PC540;BROOKS代理;質量流量控制器;BROOKS 5850E;
OMEGA ENGINEERING ;OMEGA 代理商;熱電偶接頭;熱電偶導線;熱電偶公母接頭;熱電偶感溫線;
Membrance Solution (USA) 0.22um/ 0.45um PES/ PVDF 針桶過濾膜特價供應
Membrance Solution (USA) 0.22um/ 0.45um 新款 PES 濾膜快速超低殘留型濾杯特價供應

更多

最新儀器!

力明儀器有限公司

Copyright © 2006-2017 tw17 All rights reserved.
Design: 台灣儀器網

台灣儀器網Tw17 行動條碼QR Code