Orton 玻璃軟化點(近似)試驗儀器 / Model SP-3A.
Orton
Glass Softening Point Measurement. 

 

Orton Model SP-3A system is a Quality Control instrument that was designed to quickly and simply approximate the softening point of a solid piece of glass. There is no ASTM specification for this test method.

This unit is a modified parallel plate viscometer. A solid glass piece of known dimension (approximately 0.100” thick by 3/16” by 3/16”) is placed into the sample holder and lowered into the heating chamber. The probe rod is lowered to contact the glass piece. The heater is turned on, and automatically heats up at a pre-programmed rate (25°C per minute).

As the temperature rises, the glass heats and begins to soften. The probe rod begins to penetrate the glass sample. Once the probe rod has traveled a certain distance into the glass sample, a microswitch is tripped which turns the power to the furnace off. The controller remembers the temperature at which the power was turned off. This temperature is correlated to the softening point of the glass.

 

There are three major factors that influence the reproducibility and quality of the readings from the SP-3A:

  • Sample Size: The samples must be the same approximate size, particularly the thickness. The thickness (the dimension or distance between the sample holder and the probe) is the most critical dimension. The length and width are secondary, but important as well.
  • Operator: There will be minor differences between the way different operators set the pressure on the microswitch. If all else is equal, there could be some differences in readings. It is recommended that the same operator perform all the tests.
  • Calibration: The SP-3A must be calibrated with a glass of a known softening point, such as a NIST glass. The known softening point glass should be similar in composition and melting point as the samples being tested. It is critical that the calibration samples be the same size as the test samples, particularly the thickness.

SP-3A Models

  • SP-3A - base model for testing a 3 mm x 5 mm glass sample
  • SP-3A-FGM - with modified sample holder for testing a 24 mm glass marble

Model SP-3A System Specifications                                                                                                                           

Maximum Temperature 1,000°C
Heating Element Nichrome, 500 watts
Temperature Resolution 1°C
Average Heating Rate 25°C/min.
Penetration Probe Travel 0 to 0.125” (0 to 3 mm)
Probe Travel Resolution 0.0001” (0.0025 mm)
Power Requirements 120 VAC, 15 amp, 50/60 Hz
Dimensions 8” W x 12” D x 25” T 
(200 x 300 x 640 mm)       


下載本目錄文件請使用 PDF 檔案程式
Download a brochure on the SP3A in PDF format (720 kb)

您也可能對以下商品有興趣...

產品關鍵字:

志尚儀器股份有限公司

最新廠商動態!

WHATMAN代理美國過濾耗材知名大廠;Cytiva代理WHATMAN耗材在2020年;代理濾膜;濾紙;空氣採樣濾紙;
BROOKS質量流量控制器;PC540;BROOKS代理;質量流量控制器;BROOKS 5850E;
OMEGA ENGINEERING ;OMEGA 代理商;熱電偶接頭;熱電偶導線;熱電偶公母接頭;熱電偶感溫線;
Membrance Solution (USA) 0.22um/ 0.45um PES/ PVDF 針桶過濾膜特價供應
Membrance Solution (USA) 0.22um/ 0.45um 新款 PES 濾膜快速超低殘留型濾杯特價供應

更多

最新儀器!

力明儀器有限公司

Copyright © 2006-2017 tw17 All rights reserved.
Design: 台灣儀器網

台灣儀器網Tw17 行動條碼QR Code